Ligasure-Assisted Laparoscopic Sutureless Appendectomy: A Prospective Clinical Evaluation Of Effectiveness And Benefits
Keywords:
acute appendicitis, laparoscopic appendectomy, LigaSure™, vessel sealing system, suture less surgery, stump closureAbstract
Background. Laparoscopic appendectomy has progressively replaced the open technique owing to decreased postoperative pain, earlier mobilisation, and shorter hospital stay. Ensuring secure closure of the appendiceal stump, however, remains pivotal to avert intra‑abdominal sepsis. LigaSure™ tissue‑fusion technology merges pressure with bipolar energy to provide a rapid, haemostatic seal of vessels and tissue bundles ≤ 7 mm. We prospectively evaluated the safety and efficacy of the 5‑mm LigaSure™ vessel‑sealing system for entirely suture‑less laparoscopic appendectomy.
Methods. Between July 2022 and July 2023, 57 consecutive patients with uncomplicated acute appendicitis underwent laparoscopic appendectomy at a tertiary‑care centre using LigaSure™ alone to divide the meso‑appendix and seal the appendiceal base. Demographics, operative duration, return of bowel function, length of stay (LOS), and peri‑operative complications were recorded. Data were analysed with descriptive statistics.
Results. The cohort comprised 32 males and 25 females (mean age 28.4 ± 9.6 years; range 15–65). Mean operative time was 34 ± 5.7 min; no conversion to open surgery occurred. Bowel sounds returned on postoperative day (POD) 1 in 84.2 % of patients, and oral feeds were resumed at 2.1 ± 0.5 days. Mean LOS was 3.6 ± 0.7 days. Minor morbidity was noted in three patients (5.2 %): low‑grade fever (n = 1) and superficial port‑site infection (n = 2). There were no intra‑abdominal abscesses, stump leaks, re‑operations, or mortality.
Conclusion. LigaSure™ permits a swift, single‑device, suture‑less laparoscopic appendectomy with negligible morbidity and without increasing cost in publicly funded settings. The technique obviates endo‑loops or staplers, minimises instrument exchange, and may shorten operative time. Larger randomised trials are warranted to confirm these favourable early outcomes.
Downloads
References
Addiss DG, Shaffer N, Fowler BS, Tauxe RV. The epidemiology of appendicitis and appendectomy in the United States. Am J Epidemiol. 1990;132:910–925.
Jaschinski T, Mosch C, Eikermann M, Neugebauer EA. Laparoscopic versus open appendectomy in patients with suspected appendicitis: a systematic review of meta analyses of randomised controlled trials. BMC Gastroenterol. 2015;15:48.
https://www.medtronic.com/covidien/en-us/products/vessel-sealing/ligasure-technology.html Accessed 15 May 2025.
Obonna GC, Mishra RK. Differences between Thunderbeat, LigaSure and harmonic scalpel energy systems in minimally invasive surgery. World J Lap Surg. 2014;7:41–44.
Souza LC, Ortega MR, Achar E, Simionato Netto D, Ribeiro Junior MA. Application of high frequency bipolar electrocoagulation LigaSure™ in rabbit appendix with or without acute inflammation. Acta Cir Bras. 2012;27:322–329.
Helpman L, Covens A. Laparoscopic appendectomy using the LigaSure® vessel sealing device at the time of gynaecologic surgery. J Gynecol Surg. 2012;28:188–191.
Yavuz A, Bulus H, Taş A, Aydın A. Evaluation of stump pressure in three types of appendectomy: harmonic scalpel, LigaSure, and conventional technique. J Laparoendosc Adv Surg Tech A. 2016;26:950–953.
Hamdy AA, Ayoup MF, Elsayed AA. Loop knots versus harmonic scalpel in laparoscopic appendectomy. Egypt J Hosp Med. 2018;72:4109–4112.
Raza VF, Arshad D, Bhatti LA, et al. Laparoscopic harmonic appendectomy: a novel approach. Glob J Surg. 2020;8:32–36.
Khanna S, Khurana S, Vij S. No clip, no ligature laparoscopic appendectomy. Surg Laparosc Endosc Percutan Tech. 2004;14:201–203.
Mannu GS, Sudul MK, Bettencourt Silva JH, et al. Closure methods of the appendix stump for complications during laparoscopic appendectomy. Cochrane Database Syst Rev. 2017;11:CD006537.
Pogorelić Z, Katić J, Mrklić I, et al. Lateral thermal damage of mesoappendix and appendiceal base during laparoscopic appendectomy in children: comparison of harmonic scalpel, bipolar coagulation, and thermal fusion technology. J Surg Res. 2017;212:101–107.
Downloads
Published
How to Cite
Issue
Section
License

This work is licensed under a Creative Commons Attribution 4.0 International License.
You are free to:
- Share — copy and redistribute the material in any medium or format
- Adapt — remix, transform, and build upon the material for any purpose, even commercially.
Terms:
- Attribution — You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits.

